Long-range HaLow Connectivity for Industrial IoT
PLANET HLB-1150 is an Industrial 802.11ah HaLow IIoT Remote I/O Controller designed to extend industrial monitoring and control to distributed and hard-to-wire locations. Operating over Sub-1GHz HaLow wireless connectivity, the HLB-1150 provides a flexible way to connect remote field devices with centralized monitoring systems, making it well suited for industrial facilities, unmanned sites, renewable energy applications and transportation infrastructure.
All-in-One Industrial I/O Integration
The HLB-1150 integrates 6 digital inputs, 2 digital outputs, RS-232, RS-485 and one 10/100BASE-TX Ethernet port into one compact industrial platform. By combining digital I/O, serial communication and IP networking in a single device, it simplifies the connection of alarms, status contacts, control devices and industrial equipment at remote sites.
Real-time Monitoring and Remote Control
With six digital input channels, the HLB-1150 can monitor various field conditions such as equipment alarms, cabinet door status, power failures, smoke detection and water leakage. Its two digital outputs can be used for remote actions such as activating warning devices, controlling external relays or performing equipment reset operations, enabling both monitoring and basic control from remote locations.
Flexible Serial and Modbus Device Connectivity
Built-in RS-232 and RS-485 interfaces allow the HLB-1150 to connect existing serial equipment to Ethernet and HaLow networks. Through RS-485 and Modbus integration, industrial devices such as power meters, UPS systems, inverters, environmental sensors and controllers can be connected to centralized SCADA or IIoT systems without requiring separate communication gateways.
MQTT-ready IIoT Data Communication
The HLB-1150 supports built-in MQTT Broker and MQTT Client functions for flexible IIoT data exchange. Through MQTT publish and subscribe mechanisms, field data, equipment status and I/O events can be delivered to remote platforms over Ethernet or HaLow networks, providing an efficient connection between field-level devices and SCADA, NMS, cloud and IIoT applications.
Event-driven Monitoring for Efficient Field Management
In addition to conventional status monitoring, the HLB-1150 supports event-oriented I/O operation, allowing digital input changes, trigger conditions and counter information to be monitored and recorded. This event-driven approach helps operators quickly identify changes in field conditions and respond to alarms or equipment events without relying solely on continuous polling.
Secure and Centralized Network Management
For secure and convenient device administration, the HLB-1150 supports HTTPS Web management, SNMPv3, Event Log, Syslog and SNMP Trap functions. It also supports PLANET Smart Discovery and centralized management through PLANET NMS solutions, allowing administrators to monitor distributed HLB-1150 devices and network status from a centralized platform.
Designed for Distributed Industrial Applications
With its compact industrial design, integrated I/O and serial interfaces, and HaLow wireless connectivity, the HLB-1150 is suitable for deployment in industrial machine cabinets, renewable energy sites, roadside cabinets and unmanned facilities. It provides a practical IIoT solution for extending monitoring, device communication and remote control to locations where conventional network cabling is difficult to deploy.
Unmanned Site Monitoring and Remote Control
The HLB-1150 provides an efficient solution for monitoring distributed and unmanned facilities where multiple alarm contacts and industrial devices need to be managed remotely. Its 6 digital inputs can collect signals from door sensors, intrusion alarms, smoke detectors, water leakage sensors, utility power failures and UPS alarms, while its 2 digital outputs can activate warning devices or perform remote equipment reset.
With RS-485/Modbus connectivity, devices such as UPS systems, generator controllers, power meters and environmental sensors can also be integrated into the same IIoT network. Through Ethernet or HaLow connectivity, field information can be delivered to SCADA, NMS, cloud or centralized control platforms for remote monitoring and management.
Renewable Energy Site Monitoring
For solar, wind and other distributed energy installations, the HLB-1150 helps consolidate equipment alarms, status signals and Modbus device data at remote sites.
Digital inputs can monitor inverter alarms, battery alarms, surge protection devices, cabinet doors, grid failures and generator status, while digital outputs can be used for warning indication or remote reset control. Its RS-485 interface also enables integration with power meters, inverters and battery management systems, allowing operational information to be delivered to EMS, SCADA or IIoT platforms.
Industrial Machine and Equipment Cabinet Monitoring
The HLB-1150 is ideal for industrial cabinets and equipment rooms that require centralized monitoring of multiple field signals without deploying separate communication devices.
It can monitor door status, smoke, water leakage, cooling-system alarms, power failures and UPS conditions through its digital inputs, while digital outputs provide basic remote actions such as alarm activation or relay control. RS-232 and RS-485 connectivity further enable legacy serial and Modbus devices to be integrated into an IP-based industrial network.
Transportation and Roadside Cabinet Monitoring
Roadside and transportation infrastructure often includes distributed equipment cabinets that are difficult or costly to reach with conventional network cabling.
The HLB-1150 enables remote monitoring of cabinet doors, AC/DC power failures, surge protection status, cooling fans and equipment fault signals, while supporting remote warning and reset control through its digital outputs. With HaLow wireless connectivity, field equipment can be linked back to centralized monitoring systems, making the HLB-1150 suitable for ITS, roadside cabinets and other distributed transportation applications.
Hardware
Digital I/O Monitoring and Control
Serial and Modbus Connectivity
MQTT and IIoT Features
HaLow Wireless Features
Security Features
Management Features
| Hardware Specifications | ||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ethernet Interface | 1 x 10/100BASE-TX RJ45 port | |||||||||||||||||||||||||||||||||||||||||||||
| Ethernet Features | Auto-Negotiation, Auto-MDI/MDI-X | |||||||||||||||||||||||||||||||||||||||||||||
| Antenna Connector | 1 x RP-SMA Female connector for Sub-1GHz antenna | |||||||||||||||||||||||||||||||||||||||||||||
| Serial Interface | 1 x 18-pin removable terminal block for RS485, RS232, 6 digital inputs and 2 digital outputs | |||||||||||||||||||||||||||||||||||||||||||||
| Button | 1 x RESET button Press over 5 seconds to reset the device to factory default 1 x PAIR button (function not supported in current firmware) |
|||||||||||||||||||||||||||||||||||||||||||||
| Dimensions (W x D x H) | 30 x 70 x 104 mm | |||||||||||||||||||||||||||||||||||||||||||||
| Weight | 345 g | |||||||||||||||||||||||||||||||||||||||||||||
| Power Requirements | 9~48V DC / 24V AC | |||||||||||||||||||||||||||||||||||||||||||||
| Power Consumption | 9 VDC Input No Load : 1.71W / 5.85BTU/hr Full Load : 2.07W / 7.1BTU/hr 48 VDC Input No Load : 1.92W / 6.56BTU/hr Full Load : 2.4W / 8.2BTU/hr |
|||||||||||||||||||||||||||||||||||||||||||||
| Enclosure | Metal | |||||||||||||||||||||||||||||||||||||||||||||
| IP Rating | IP30 | |||||||||||||||||||||||||||||||||||||||||||||
| Installation | DIN-rail / Wall-mount | |||||||||||||||||||||||||||||||||||||||||||||
| LED Indicators | Power, LINK/ACT, I/O and RF signal strength x 3 | |||||||||||||||||||||||||||||||||||||||||||||
| Wireless Interface Specifications | ||||||||||||||||||||||||||||||||||||||||||||||
| Standard | IEEE 802.11ah (Wi-Fi HaLow) Compliance with regional regulatory requirements (FCC, ETSI) |
|||||||||||||||||||||||||||||||||||||||||||||
| Band Mode | Sub-1 GHz frequency operation | |||||||||||||||||||||||||||||||||||||||||||||
| Frequency Range | 902~928 MHz : North America 868 MHz : European Union |
|||||||||||||||||||||||||||||||||||||||||||||
| Wireless Mode | Access Point / Station | |||||||||||||||||||||||||||||||||||||||||||||
| Security | WPA3 Personal | |||||||||||||||||||||||||||||||||||||||||||||
| Operating Channels (US) | Sub1G: 1MHz 1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25, 27, 29, 31, 33, 35,37, 39, 41, 43, 45, 47, 49, 51 (Channels) 2MHz 2, 6, 10, 14, 18, 22, 30, 34, 38, 42, 46, 50 (Channels) 4MHz 8, 16, 24, 32, 40, 48 (Channels) 8MHz 12, 28, 44 (Channels) |
|||||||||||||||||||||||||||||||||||||||||||||
| Operating Channels (EU) | Sub1G: 1MHz 1, 3, 5, 7, 9 |
|||||||||||||||||||||||||||||||||||||||||||||
| Max. Transmit Power (dBm) | 21 dBm (Typical) @ MCS0 * Actual transmit power is subject to regional regulatory requirements. |
|||||||||||||||||||||||||||||||||||||||||||||
| Receive Sensitivity (US) |
|
|||||||||||||||||||||||||||||||||||||||||||||
| Receive Sensitivity (EU) |
|
|||||||||||||||||||||||||||||||||||||||||||||
| Digital Input Specifications | ||||||||||||||||||||||||||||||||||||||||||||||
| Channels | 6 (DI0-DI5) | |||||||||||||||||||||||||||||||||||||||||||||
| Input Type | Wet Contact (Sink/Source) / Dry Contact | |||||||||||||||||||||||||||||||||||||||||||||
| Wet Contact - ON Voltage Level | 10–50V DC | |||||||||||||||||||||||||||||||||||||||||||||
| Wet Contact - OFF Voltage Level | Open / below 4V DC | |||||||||||||||||||||||||||||||||||||||||||||
| Dry Contact - ON/OFF Status | Close to GND / Open | |||||||||||||||||||||||||||||||||||||||||||||
| Photo Isolation | 3750 VDC | |||||||||||||||||||||||||||||||||||||||||||||
| Input Functions | Status monitoring, trigger condition and counter | |||||||||||||||||||||||||||||||||||||||||||||
| Digital Output Specifications | ||||||||||||||||||||||||||||||||||||||||||||||
| Channels | 2 (DO0-DO1) | |||||||||||||||||||||||||||||||||||||||||||||
| Output Type | Open collector (Sink) | |||||||||||||||||||||||||||||||||||||||||||||
| Load Voltage | 3.5~50V | |||||||||||||||||||||||||||||||||||||||||||||
| Max. Load Current | 700 mA per channel | |||||||||||||||||||||||||||||||||||||||||||||
| Photo Isolation | 3750 VDC | |||||||||||||||||||||||||||||||||||||||||||||
| Serial Interface Specifications | ||||||||||||||||||||||||||||||||||||||||||||||
| Serial Ports | 1 x RS-232 and 1 x RS-485 via removable terminal block | |||||||||||||||||||||||||||||||||||||||||||||
| Serial Standards | RS-232 / RS-485 (2-wire RS-485) | |||||||||||||||||||||||||||||||||||||||||||||
| Baud Rate (Data Rate) | 300bps to 115200bps | |||||||||||||||||||||||||||||||||||||||||||||
| Data Bits | RS-232: 5, 6, 7, 8 RS-485: 8 |
|||||||||||||||||||||||||||||||||||||||||||||
| Parity Type | RS-232: Odd, Even, None, Space, Mark RS-485: Odd, Even, None |
|||||||||||||||||||||||||||||||||||||||||||||
| Stop Bit | 1, 2 | |||||||||||||||||||||||||||||||||||||||||||||
| Flow Control | None, XON/XOFF (RS-232 only) | |||||||||||||||||||||||||||||||||||||||||||||
| Signals | RS-232: TxD, RxD, GND 2-wire RS-485: D+, D-, GND |
|||||||||||||||||||||||||||||||||||||||||||||
| Operation Mode | RS-232: TCP Server; RS-485: Modbus RTU/TCP applications | |||||||||||||||||||||||||||||||||||||||||||||
| Software Features | ||||||||||||||||||||||||||||||||||||||||||||||
| LAN | Static IP / Dynamic IP | |||||||||||||||||||||||||||||||||||||||||||||
| Wireless Mode | Access Point Station |
|||||||||||||||||||||||||||||||||||||||||||||
| Channel Width | US915: 1MHz, 2MHz, 4MHz, 8MHz EU868: 1MHz |
|||||||||||||||||||||||||||||||||||||||||||||
| SSID Broadcast | Enable / Disable | |||||||||||||||||||||||||||||||||||||||||||||
| Status Monitoring | Device status, wireless client List PLANET Smart Discovery System Log supports remote syslog server |
|||||||||||||||||||||||||||||||||||||||||||||
| Security | ||||||||||||||||||||||||||||||||||||||||||||||
| Wireless Security | WPA3 Personal | |||||||||||||||||||||||||||||||||||||||||||||
| Secure Web Management | HTTPS / TLS v1.3 | |||||||||||||||||||||||||||||||||||||||||||||
| Secure Network Management | SNMPv3 | |||||||||||||||||||||||||||||||||||||||||||||
| MQTT Security | TLS encryption | |||||||||||||||||||||||||||||||||||||||||||||
| MQTT Authentication | Username / Password | |||||||||||||||||||||||||||||||||||||||||||||
| Password Security | Unique default password for enhanced device access security | |||||||||||||||||||||||||||||||||||||||||||||
| Management | ||||||||||||||||||||||||||||||||||||||||||||||
| Basic Management Interfaces | Web browser SNMP v1/v2c PLANET Smart Discovery utility and NMS controller supported |
|||||||||||||||||||||||||||||||||||||||||||||
| System Log | System Event Log | |||||||||||||||||||||||||||||||||||||||||||||
| Others | Setup wizard Dashboard System status/service Statistics Connection status Auto reboot/Diagnostics Remote management through PLANET DDNS/Easy DDNS Configuration backup and restore Supports UPnP Diagnostics |
|||||||||||||||||||||||||||||||||||||||||||||
| Central Management | PLANET NMS Controller, PLANET CloudNMS | |||||||||||||||||||||||||||||||||||||||||||||
| Environment & Certification | ||||||||||||||||||||||||||||||||||||||||||||||
| Temperature | Operating: -40~75 degrees C Storage: -40~75 degrees C |
|||||||||||||||||||||||||||||||||||||||||||||
| Humidity | Operating: 10 ~ 90% (non-condensing) Storage: 5 ~ 90% (non-condensing) |
|||||||||||||||||||||||||||||||||||||||||||||
| Regulatory | HLB-1150-US915: FCC, RoHS HLB-1150-EU868: CE, RoHS |
|||||||||||||||||||||||||||||||||||||||||||||
| Ordering Information | |
|---|---|
HLB-1150-US915 |
Industrial 802.11ah HaLow IIoT Remote I/O Controller with 6DI, 2DO and RS-232/485(US915 Sub-1G) |
HLB-1150-EU868 |
Industrial 802.11ah HaLow IIoT Remote I/O Controller with 6DI, 2DO and RS-232/485(EU868 Sub-1G) |
Industrial 802.11ah HaLow IIoT Remote I/O Controller with 6DI, 2DO and RS-232/485