Ethernet-based Connectivity for Industrial IoT
PLANET IIC-1150 is an Industrial IIoT Remote I/O Controller designed for Ethernet-based monitoring and control of field equipment. With integrated digital I/O and serial interfaces, it connects industrial devices to centralized monitoring systems over a wired IP network.
All-in-One Industrial I/O Integration
The IIC-1150 integrates 6 digital inputs, 2 digital outputs, RS-232, RS-485 and one 10/100BASE-TX Ethernet port into one compact industrial platform. By combining digital I/O, serial communication and IP networking in a single device, it simplifies the connection of alarms, status contacts, control devices and industrial equipment at remote sites.
Real-time Monitoring and Remote Control
With six digital input channels, the IIC-1150 can monitor various field conditions such as equipment alarms, cabinet door status, power failures, smoke detection and water leakage. Its two digital outputs can be used for remote actions such as activating warning devices, controlling external relays or performing equipment reset operations, enabling both monitoring and basic control from remote locations.
Flexible Serial and Modbus Device Connectivity
Built-in RS-232 and RS-485 interfaces allow the IIC-1150 to connect existing serial equipment to Ethernet networks. RS-485 and Modbus integration help connect power meters, UPS systems, inverters, environmental sensors and controllers to centralized SCADA or IIoT systems.
MQTT-ready IIoT Data Communication
The IIC-1150 supports built-in MQTT Broker and MQTT Client functions for flexible IIoT data exchange. Through MQTT publish and subscribe mechanisms, field data, equipment status and I/O events can be delivered to remote platforms over wired Ethernet networks, providing an efficient connection between field-level devices and SCADA, NMS, cloud and IIoT applications.
Event-driven Monitoring for Efficient Field Management
In addition to conventional status monitoring, the IIC-1150 supports event-oriented I/O operation, allowing digital input changes, trigger conditions and counter information to be monitored and recorded. This event-driven approach helps operators quickly identify changes in field conditions and respond to alarms or equipment events without relying solely on continuous polling.
Secure and Centralized Network Management
For secure and convenient device administration, the IIC-1150 supports HTTPS Web management, SNMPv3, Event Log, Syslog and SNMP Trap functions. It also supports PLANET Smart Discovery, centralized management via PLANET NMS Controller and cloud-based management via PLANET CloudNMS, enabling administrators to monitor and manage distributed IIC-1150 devices over wired Ethernet networks.
Designed for Distributed Industrial Applications
With its compact industrial design, integrated I/O and serial interfaces, and Ethernet connectivity, the IIC-1150 is suitable for industrial machine cabinets, renewable energy sites, roadside cabinets and unmanned facilities with wired network access.
Unmanned Site Monitoring and Remote Control
The IIC-1150 provides an efficient solution for monitoring distributed and unmanned facilities where multiple alarm contacts and industrial devices need to be managed remotely. Its 6 digital inputs can collect signals from door sensors, intrusion alarms, smoke detectors, water leakage sensors, utility power failures and UPS alarms, while its 2 digital outputs can activate warning devices or perform remote equipment reset.
With RS-485/Modbus connectivity, devices such as UPS systems, generator controllers, power meters and environmental sensors can also be integrated into the same IIoT network. Through Ethernet connectivity, field information can be delivered to SCADA, NMS, cloud or centralized control platforms for remote monitoring and management.
Renewable Energy Site Monitoring
For solar, wind and other distributed energy installations, the IIC-1150 helps consolidate equipment alarms, status signals and Modbus device data at remote sites.
Digital inputs can monitor inverter alarms, battery alarms, surge protection devices, cabinet doors, grid failures and generator status, while digital outputs can be used for warning indication or remote reset control. Its RS-485 interface also enables integration with power meters, inverters and battery management systems, allowing operational information to be delivered to EMS, SCADA or IIoT platforms.
Industrial Machine and Equipment Cabinet Monitoring
The IIC-1150 is ideal for industrial cabinets and equipment rooms that require centralized monitoring of multiple field signals without deploying separate communication devices.
It can monitor door status, smoke, water leakage, cooling-system alarms, power failures and UPS conditions through its digital inputs, while digital outputs provide basic remote actions such as alarm activation or relay control. RS-232 and RS-485 connectivity further enable legacy serial and Modbus devices to be integrated into an IP-based industrial network.
Transportation and Roadside Cabinet Monitoring
Transportation and roadside infrastructure often includes distributed equipment cabinets that require reliable monitoring of equipment status and environmental conditions.
The IIC-1150 enables monitoring of cabinet doors, AC/DC power failures, surge protection status, cooling fans and equipment fault signals through its digital inputs. Its digital outputs support remote warning and reset control. With wired Ethernet connectivity, field information can be transmitted to centralized monitoring systems, making the IIC-1150 suitable for ITS, roadside cabinets and other transportation applications with existing Ethernet infrastructure.

Hardware
Digital I/O Monitoring and Control
Serial and Modbus Connectivity
MQTT and IIoT Features
Security Features
Management Features
| Hardware Specifications | |
|---|---|
| Ethernet Interface | 1 x 10/100BASE-TX RJ45 port |
| Ethernet Features | Auto-Negotiation, Auto-MDI/MDI-X |
| Serial Interface | 1 × 18-pin removable terminal block for RS-485, RS-232, 6 digital inputs and 2 digital outputs |
| Button | 1 x RESET button Press over 5 seconds to reset the device to factory default |
| Dimensions (W x D x H) | 30 × 70 × 104 mm |
| Weight | 345 g |
| Power Requirements | 9~48V DC / 24V AC |
| Power Consumption | 9 VDC Input: No Load: 1.71W/5.8BTU/hr; Full Load: 2.07W/7.1BTU/hr 48 VDC Input: No Load: 1.92W/6.5BTU/hr; Full Load: 2.4W/8.2BTU/hr |
| Enclosure | Metal |
| IP Rating | IP30 |
| Installation | DIN-rail / Wall-mount |
| LED Indicators | Power, LINK/ACT, I/O |
| Standard | Compliance with regional regulatory requirements (FCC, ETSI) |
| Digital Input Specifications | |
| Channels | 6 (DI0-DI5) |
| Input Type | Wet Contact (Sink/Source) / Dry Contact |
| Wet Contact - ON Voltage Level | 10–50V DC |
| Wet Contact - OFF Voltage Level | Open / below 4V DC |
| Dry Contact - ON/OFF Status | Close to GND / Open |
| Photo Isolation | 3750 VDC |
| Input Functions | Status monitoring, trigger condition and counter |
| Digital Output Specifications | |
| Channels | 2 (DO0-DO1) |
| Output Type | Open collector (Sink) |
| Load Voltage | 3.5~50V |
| Max. Load Current | 700 mA per channel |
| Photo Isolation | 3750 VDC |
| Serial Interface Specifications | |
| Serial Ports | 1 x RS-232 and 1 x RS-485 via removable terminal block |
| Serial Standards | RS-232 / RS-485 (2-wire RS-485) |
| Baud Rate (Data Rate) | 300bps to 115200bps |
| Data Bits | RS-232: 5, 6, 7, 8 RS-485: 8 |
| Parity Type | RS-232: Odd, Even, None, Space, Mark RS-485: Odd, Even, None |
| Stop Bit | 1, 2 |
| Flow Control | None, XON/XOFF (RS-232 only) |
| Signals | RS-232: TxD, RxD, GND 2-wire RS-485: D+, D-, GND |
| Operation Mode | RS-232: TCP Server; RS-485: Modbus RTU/TCP applications |
| Software Features | |
| LAN | Static IP / Dynamic IP |
| Status Monitoring | Device status, Ethernet status PLANET Smart Discovery System Log supports remote syslog server |
| Security | |
| Secure Web Management | HTTPS / TLS v1.3 |
| Secure Network Management | SNMPv3 |
| MQTT Security | TLS encryption |
| MQTT Authentication | Username / Password |
| Password Security | Unique default password for enhanced device access security |
| Management | |
| Basic Management Interfaces | Web browser SNMP v1/v2c PLANET Smart Discovery utility and NMS controller supported |
| System Log | System Event Log |
| Others | Setup wizard Dashboard System status/service Statistics Connection status Auto reboot/Diagnostics Remote management through PLANET DDNS/Easy DDNS Configuration backup and restore Supports UPnP Diagnostics |
| Central Management | PLANET NMS Controller, PLANET CloudNMS |
| Environment & Certification | |
| Temperature | Operating: -40~75 degrees C Storage: -40~75 degrees C |
| Humidity | Operating: 10 ~ 90% (non-condensing) Storage: 5 ~ 90% (non-condensing) |
| Regulatory | CE, FCC, RoHS |
| Date | Version | Description | Download |
|---|---|---|---|
| 2026-11-20 | 1.0 | IIC-1150 |
|
| Date | Version | Description | Download |
|---|---|---|---|
| 2026-11-27 | 1.0 | Initial release. |
|
| Photo | Model | Description |
|---|
| Ordering Information | |
|---|---|
IIC-1150 |
Industrial IoT I/O Controller with 6DI, 2DO and RS-232/485 |
Industrial IoT I/O Controller with 6DI, 2DO and RS-232/485