[IHD-410PT/IHD-410PR] The output monitor which is connecting to IHD-410PR does not display any video or show wrong color video. How can I fix it?


The IHD-410PR might not copy the correct EDID. Please refer the following:

  1. The output monitor should be a real HDMI monitor; do not use DVI-to-HDMI or any converter.
    EDID (Extended Display Identification Data) is greatly important which contains information about manufacturer name and serial number, product type, maximum image size, color characteristics, factory pre-set timings, frequency range limits, etc. In some cases, it displays problems that may occur due to the incorrect EDID communication between the display monitor and the unit or inappropriate EDID data programmed by display manufacturers. Therefore, by adopting “EDID COPY” function, it will allow the system to copy EDID information from EDID compliant displays in order to assure accurate display performance.
    However, owing to a variety of monitor models, EDID data may not be usable to all. For example, if you use a DVI-to-HDMI converter to a real DVI monitor, the copied EDID (HDMI) data may not be applicable to DVI monitors.

  2. Please get into the IHD-410PR’s web management to copy EDID manually.