The GSW-1600HP is designed with over power loading protection functions. Please make sure that your total PoE output is within 220Watts. If your PD device is the IEEE 802.3at (standard) and it needs 24Watts for powering up, the GSW-1600HP only can power up to 9 of your PD devices.
A: Solution:
The WGSD-10020 supports SFP type auto-detection. However, some of the SFP transceiver can not report the type information at the moment of plug into the slot. As a result, WGSD-10020 could encounter the detection / synchronization issue and can not runs smoothly.
In such circumstance, we would suggest to pre-setup the port(s) that is going to attach 100Base-FX SFP transceiver to 100 Force mode in the Web page (as figure below), that shall make the connection error free.
Please refer to the table below:
Model | FSD-808HP | |
PoE Budget | 140W | |
PoE Ability
| Number of Class 1 PD, <3.8W | 8 |
Number of Class 2 PD, <6.5W | 8 | |
Number of Class 3 PD, <12.9W | 8 | |
Number of Class 4 PD, 25W | 5 | |
Input Power | 100~240V AC / 50-60Hz |
At temperature 0 ~ 40 degrees C range, FNSW-2400PS PoE output can achieve 100%. Due to the PSU hardware design, if the temperature arises up to 50 Degree C, it will reduce 20% of Power Budget and higher temperature will reduce the total output power as a result.
At temperature 0 ~ 40 Degrees C range, FNSW-1600P PoE output can achieve 100%. Due to the PSU hardware design, if the temperature arises up to 50 Degree C, it will reduce 20% of Power Budget and higher temperature will reduce the total output power as a result.
Solution:
Yes, please refer to Appendix B 802.1Q VLAN Setting example from GSW-4804SF user's manual for reference.
Solution:
No, this RS232 console interface was designed for reset the GSW-4804SF to factory default mode. Not for the switch management purpose.